TMV servicing and testing record
A service and test record for thermostatic mixing valves (TMVs). Record the thermometer used, then add each valve: its location and outlet, scan its tag, the valve type, set and measured mixed temperatures, the fail-safe test with the cold supply isolated, and whether strainers were cleaned. The form warns when the mixed temperature is above 44°C, records the action and the temperature after adjustment, counts the valves that pass and fail, and ends with actions and sign-off. Every question is listed below, and you can fill the live form in on this page.
Ready to use from the form library, and every question is yours to edit. Trial from £1, cancel any time.
Try it on your phone
Try it on this phone
Fill in the TMV servicing on your phone now
See how the TMV servicing looks on your phone
Scan the code with your phone camera. It opens the real form, no sign-up needed.
Open the live example and fill it in, just as your team would on site. No sign-up needed.
See it on this phoneEvery question is editable. Add this form to your account, then change the wording, add or remove questions and options, and make it fit your own jobs.
What does a TMV service involve?
A TMV service checks each valve's mixed water temperature against its set point with a thermometer, tests the fail-safe with the cold supply isolated, cleans the strainers and check valves, and records the result and any adjustment. HSE says TMVs need regular routine maintenance by competent people in line with the manufacturer's instructions, and that strainers or filters should be inspected, cleaned, descaled and disinfected annually or as the risk assessment says.
Last updated . Facts checked by the SiteSurvey team on 17 October 2026 against HSE: scalding and burning, HSE HSG274 Part 2: control of legionella in hot and cold water systems (TMVs) and HSE HSIS6: managing the risk from hot water and surfaces in health and social care.
Try the TMV servicing form live
Answer a few questions and watch it adapt. Your answers are not saved, and any photos you add are deleted within the hour.
Open the completed example to see fictional readings, notes, photos and calculations. Choose Blank form to try entering your own answers.
Want to see one filled in? See a completed TMV servicing report (PDF), made by SiteSurvey from a fictional site visit.
Every question in the TMV servicing template
A thermostatic mixing valve (TMV) service record: each valve with its location, outlet and type, set and measured mixed temperatures, fail-safe test, strainers and result, with a warning above 44°C. 3 sections and 56 questions. Follow-up questions and guidance appear only when an answer calls for them, so the person on site never sees the ones that do not apply.
Make it your own: every question is editable
This is a starting point, not a fixed form. Once it is in your SiteSurvey account you can reword any question, add or remove questions, sections and answer options, and add your own logo, so it fits the way your team works and the jobs you do.
Details you only enter once
Add this form to a project in SiteSurvey and it fills in what the project already knows, so nobody on site retypes it and every form on the job uses the same names. Anything filled in can still be changed.
- Project: the project name
- Client: the project's customer
- Site: the site, when the form is opened for a space or a product
- Site address: the site address, from the space or the project
Visit
- ProjectShort answerFills in from the project name
- ClientShort answerFills in from the project's customer
- Site*Short answerFills in from the site, when the form is opened for a space or a product
- Site addressShort answerFills in from the site address, from the space or the project
- Service date*Date
- TimeTime
- Engineer*Short answer
- Thermometer and calibration dateShort answer
- Allowed difference from the set temperature (± K)Number
From the valve maker's instructions or your water safety plan. The form sets none; leave it blank to record the difference only.
- GuidanceHSE: where vulnerable people are at risk from scalding during whole-body immersion, water temperatures must not exceed 44°C. Where hot water is stored and distributed hot to control legionella, baths and showers should be fitted with TMVs, and outlet temperatures and TMVs should be monitored and maintained so the controls stay effective. HSE says TMVs need regular routine maintenance by competent people, in line with the manufacturer's instructions.
- GuidanceSources: HSE HSG274 Part 2 (legionella control in hot and cold water systems) on TMVs and outlet temperatures, the NHS Model Engineering Specification D08 (thermostatic mixing valves, healthcare premises) and the BuildCert TMV2 (domestic, BS EN 1111 and BS EN 1287) and TMV3 (healthcare) approval schemes. D08 sets maximum mixed temperatures for each outlet type that are lower than 44°C for showers, basins and bidets: enter the figure for each valve from D08 or the site water safety plan. D08 asks for in-service checks a few weeks and again a few months after commissioning, then at an interval set from the results.
Valves
- Valves by room or wardRepeat for each entry. Each one asks:
- Room or ward*Short answer
For example Ward 4 assisted bathroom or Flat 12
- Valves in this roomRepeat for each valve. Each one asks:
- Outlet in this room*Short answer
- Scan the valve tagScan a label: asset number, serial number
Optional. Scan the label or tag to capture its numbers.
- OutletChoose one
- Bath
- Shower
- Basin
- Bidet
- Sink
- Other
- ValveChoose one
- TMV2
- TMV3
- Other
- Set mixed temperature (°C)Number
- Measured mixed temperature (°C)*Number
- Maximum mixed temperature for this outlet (°C)Number
From D08 or the site water safety plan for this outlet type.
- Against the outlet maximumWorked out by the formShown only when the answers above make it relevant
- CheckAbove the maximum for this outlet type. Reset the valve and retest.Shown only when the answers above make it relevant
- Measured minus set (K)Worked out by the formShown when “Measured mixed temperature (°C)” is answered and “Set mixed temperature (°C)” is answered
- Against the allowed differenceWorked out by the formShown when “Measured minus set (K)” is answered and “Allowed difference from the set temperature (± K)” is answered
- WarningAbove 44°C. Reset or repair the valve before the outlet is used.Shown only when the answers above make it relevant
- Fail-safe test (cold supply isolated)Choose one
- Pass
- Fail
- Strainers and check valves cleaned?Yes or No
- Result*Choose one
- Pass
- Fail
- Action takenNotesShown only when the answers above make it relevant
- Mixed temperature after adjustment (°C)NumberShown only when the answers above make it relevant
- Mixed temperature as left (°C)Worked out by the form
The temperature after adjustment if there is one, otherwise the measured temperature.
Shown when “Measured mixed temperature (°C)” is answered - Photos (valve, tag and thermometer reading)Photos
- This room: valves failedWorked out by the form
- This room: valves passedWorked out by the form
- This room: valves recordedWorked out by the form
- This room: above 44°C as foundWorked out by the form
- This room: above 44°C as leftWorked out by the form
- This room: fail-safe test failedWorked out by the form
- This room: outside the allowed differenceWorked out by the form
- This room: strainers not cleanedWorked out by the form
- This room: above the outlet maximum as foundWorked out by the form
- Valves failedWorked out by the form
- Valves passedWorked out by the form
- Valves recordedWorked out by the form
- Above 44°C as foundWorked out by the form
- Above 44°C as leftWorked out by the form
- Fail-safe test failedWorked out by the form
- Outside the allowed differenceWorked out by the form
- Strainers not cleanedWorked out by the form
- Above the outlet maximum as foundWorked out by the form
- WarningAn outlet was left above 44°C. Take it out of use, tell the person in charge and record who and when under further actions.Shown only when the answers above make it relevant
Actions and sign-off
- Are further actions needed?Yes or No
- Further actionsRepeat for each action. Each one asks:Shown when “Are further actions needed?” is Yes
- What needs doing?*Notes
- PriorityChoose one
- Urgent
- High
- Medium
- Low
- Who will do it?Short answer
- Due dateDate
- StatusChoose one
- Open
- In progress
- Completed
- Inspector name*Short answer
- Position or companyShort answer
- Inspector signatureSignature
- CheckSigning records what was found on the day. It does not make unsafe equipment safe or replace a thorough examination, design check or service by a competent person.
- Next TMV service dueDate
Set from D08 and the results of this service.
- Days to the next serviceWorked out by the formShown when “Service date” is answered and “Next TMV service due” is answered
- CheckThe next due date is before the date of this visit. Check the date.Shown only when the answers above make it relevant
See it filled in
A completed TMV servicing report, made by SiteSurvey from a fictional site visit: every answer, the photos, the guidance that applied and the sign-off, ready to send as a PDF.
TMV servicing FAQs
What temperature is safe?
Where vulnerable people are at risk from scalding during whole-body immersion, HSE says water temperatures must not exceed 44°C. The form warns above 44°C.
What is the fail-safe test?
HSE says type 3 TMVs are pre-set and fail-safe, and should be checked regularly to make sure they fail safe if the cold water supply pressure is interrupted. The form records the test, with the cold supply isolated, for each valve.
TMV2 or TMV3?
HSE's HSG274 says type 2 TMVs, which users can override, are required by building regulations where the scalding risk is low. Pre-set type 3 TMVs should be fitted where the risk is significant and are required at healthcare premises. The form records the type of each valve.
How does it fit with legionella control?
Where hot water is stored above 60°C and distributed above 50°C to control legionella, HSE says baths and showers should be fitted with TMVs so water temperatures do not exceed 44°C. Keep this record with your legionella temperature checks.
Can I scan each valve?
Yes. Tag each valve and scan it on the SiteSurvey app, so readings stay with the right valve visit to visit.
Who uses this?
Water hygiene engineers, plumbers, care homes, schools, hospitals and facilities teams.
Related
Related templates
Templates that go with the TMV servicing form
A shower head and hose descaling record for legionella control: each outlet with its location, condition, descale and disinfection, temperatures and result, against the HSG274 quarterly frequency.
A legionella monthly temperature log: hot and cold sentinel outlet readings, cylinder flow and return temperatures and TMV inlets, with warnings when a reading misses the HSE target.
A weekly flushing record for little-used outlets: each tap, shower and hose with how long it was flushed, whether it was done without spray, the temperature reached and showerhead cleaning dates.
Legionella risk assessment for a hot and cold water system: who is responsible, tanks and heaters, outlet temperatures, little-used outlets, findings and actions.
Use this TMV servicing form with your team
Add it from the form library in one click, change any question, and every completed form becomes a branded PDF report.
Start your trial →